Stainless Steel Filters for Harsh Environments
SS316 / SS304 ¼”, ½”, 1”

COALESER FILTER / MIST FILTERS


AGI Gas and Liquid Sample Analyser Filters protect analysers from sample impurities by removing solids and liquids from gases with 99.99999+% efficiency at 0.01 micron. AGI Sample Filters offer liquid filtration to 1 micron or lower. Composed of borosilicate glass microfibers with a resin binder, AGI sample filters are inert to most any gas or liquid. To satisfy the extremely wide range of requirements for analyser sample filters, AGI supplies a complete line of filter housings in stainless steel, polypropylene, and other corrosion resistant materials, as well as a choice of high efficiency filter elements which are inert to most all liquids and gases.

Microfiber Filter Cartridges efficiently separate suspended liquids from gases. The micro fibres capture the fine liquid droplets suspended in the gas and cause the droplets to run together to form large drops within the depth of the filter cartridge. The large drops, forced by the gas, flow to the downstream surface of the filter cartridge, from which the liquid drains by gravity. This process is called “coalescing”. Since the coalesced liquid drains from the cartridge at the same rate that liquid droplets enter the cartridge, the cartridge has an unlimited life when coalescing liquids from relatively clean gases, and the filters operate at their initial retention efficiency even when wet with liquid. Note that the flow direction is inside-to-outside, to permit the liquid to drip from the outside of the filter to the housing drain. Since the coalesced liquid drips from the downstream surface of the filter cartridge in the presence of filtered gas, it is important to avoid carryover, or entrainment, of liquid droplets by the gas leaving the filter housing. The coarse, rapidly-draining outer layer ensures that the liquid drips continuously from the bottom of the filter cartridge and minimizes the chance of liquid carryover.

• Remove liquids and solids from gas samples
• Remove solids and gas bubbles from liquid samples
• Coalesce and separate two liquid phases
• Filter solids and liquids from gases with 99.99999+% efficiency at 0.01 µm
• Temperature resistance to 900°F (482°C)
• Low pressure drop
• Long life between filter element

APPLICATION
• Emissions Monitoring and Analysis
• Slip Stream and By-Pass Sampling Filtration
• Process Instrumentation and Controls
• Specialty Gas and Chemical Filtration


STAINLESS STEEL IN LINE PROCESS FILTERS

Adsorbent Grade Use For
Carbon 000 Compressor oil vapors, C5 and heavier hydrocarbons, aromatics, oxygenated hydrocarbons, chlorinated organics, freons, carbon disulfide.
Silica Gel 101 Recommended only for water vapor.
Molecular Sieve Type 13X 103 Most C4 and lighter hydrocarbons, ethylene, propylene, acetylene, ethylene oxide, ammonia, mercaptans, sulfur hexa-fluoride, triethylamine, and smaller aminies.
Mixed Sodium & Calcium Hydroxides 107 All acidic gases, including sulfur trioxide, sulfur dioxide, nitrogen dioxide, carbon dioxide, hydrogen sulfide, hydrogen chloride. Phosphorus trichloride. Boron trifluoride.



HUMIDITY REMOVAL PANEL USING
SILICA GEL / COTTON FILTER


HUMIDITY REMOVAL PANEL USING SILICA GEL / COTTON FILTER